Modular Refrigeration Unit (MRU)
-
Quadcon Refrigerated Container System (QRCS)
-
TriCon Refrigerated Container System (TRCS)
Refrigeration
Modular Refrigeration Unit (MRU)
![MRU_GREEN_IMGP7080031616_SWOOSH](https://mainstream-engr.com/wp-content/uploads/2021/09/MRU_GREEN_IMGP7080031616_SWOOSH.png)
![MRU-TAN_062113_26_SWOOSH](https://mainstream-engr.com/wp-content/uploads/2021/09/MRU-TAN_062113_26_SWOOSH.png)
Tested to U.S. Military Standard 810 – Official Modular Refrigeration Unit used by the U.S. Military
- Designed for high ambient temperatures and desert conditions
- Designed for maintenance or repair with common tools from standard military tool kits
- Mean Time Between Failure (MTBF) rate of 5,202 hours
- 20-year storage life without performance degradation
- Designed for maintenance or repair with common tools from standard military tool kits
- Straightforward, intuitive control panel
- Integrated LCD that simplifies temperature and defrost settings
- 18 LED status indicators and nine jumpers located on the PCB allow user override of sensors and relays
- Wire harnesses are straightforward plug and play
- Brazing, soldering or wire splicing never required
Physical | ||
---|---|---|
Height | 21.4 inches | 54.3 cm |
Width | 36.8 inches | 93.3 cm |
Depth | 38 inches | 96.5 cm |
Weight | 350 lbs | 158.8 kg |
Electrical Power | ||
---|---|---|
MRU-TQ1-404 | 120 VAC, single-phase, 60Hz | |
MRU-TQ3-404 | 208 VAC, 3-phase, 50/60 Hz Y Connection w/Neutral |
Cooling Capacity | ||
---|---|---|
MRU-TQ1-404 | 2,800 BTU/hr (820 W) at 0°F/100°F | 6,600 Btu/hr (1,933 W) at 35°F/100°F |
MRU-TQ3-404 | 4,100 Btu/hr (1,200 W) at 0°F/100°F | 9,750 Btu/hr (2,857 W) at 35°F/100°F |
Refrigerant | R-404A | 6 lbs 8 oz |
Set Up Time – The MRU can be installed in less than 30 minutes by two personnel and is operable by a soldier outfitted in all levels of Mission Oriented Protective Posture (MOPP) equipment. The MRU requires less than 90 minutes Mean Time To Repair (MTTR) including evacuation and recharging using standard, commercial support and test equipment. |
---|
Contact: Send us an email – militarysales@mainstream-engr.com
Phone: 321-631-3550
Container
Quadcon Refrigerated Container System (QRCS)
![qrcs-mru-3quarter-mru-side_7271_GREEN_SWOOSH](https://mainstream-engr.com/wp-content/uploads/2021/09/qrcs-mru-3quarter-mru-side_7271_GREEN_SWOOSH.png)
Mainstream’s Quadcon Refrigerated Container System (QRCS) is approved by the United Sates Marine Corps (USMC). QRCS is a six-foot ten-inch by eight-foot by four-foot nine-inch (6’10” X 8’ X 4’9”) insulated container with Mainstream’s Modular Refrigeration Unit (MRU) that is powered by an external power source and capable of storing and transporting temperature sensitive cargo. Our MRU maintains the insulated container at freezer or refrigerator temperature ranges in ambient temperatures ranging from -25 to +125°F. Mainstream’s QRCS is certified by NSF International to satisfy sanitary requirements of NSF ANSI 7 Standard for Commercial Refrigerators and Freezers. It is ISO 1496-2 tested and CSC approved. The QRCS operates with 208 VAC, 50/60 Hz, three-phase power input or 120 VAC, 60 Hz, single-phase power.
Tested to U.S. Military Standard 810
Official Modular Refrigeration Unit approved USMC
- Electrically Powered RU with Full-Width Double Door
- Verified to Meet MIL PRF 32335 Requirements
- ISO Tested and CSC Approved
- NSF/ANSI Standard 7 Certified
- High Efficiency with Energy Saver Option
- MTBF 5,022 hrs.
- 20 Year Storage
QRCS/MRU Value-Added Features
Designed for Military Environment
The MRU was designed for the harsh military environment. The unit has been tested to MIL STD 810G (e.g., salt-fog, humidity, sand-dust, solar, ice & freezing rain, blowing rain and watertightness, EMI [RE102 and CE102], high and low temperature operation & storage, ground mobility, rail impact and transit drop).
Improved Air Flow and Air Circulation
Air is drawn into the evaporator so condensation is not sprayed onto the food inside the container. The conditioned air circulates from the evaporator compartment to provide more uniform air flow distribution and prevent air blockage.
Total Unit Modularity
Every component can be replaced with common tools. Tube brazing or wire splicing is never required.
System Redundancy
Component redundancy allows the MRU to operate even if a condenser fan, evaporator fan, fan capacitor or heater fails. Extra terminals are available on the relays if a contact pits and fails.
Energy Saver Option
In freezer mode, an energy saver selection switch automatically operates the MRU longer during cooler periods of the day, such as the evening, to reduce power consumption.
Circuit Breakers
The MRU uses re-settable circuit breakers. There are no fusible links or fuses.
Physical | ||
---|---|---|
Size | 82″H X 96″L X 57″W | |
Doors | full-width double door | |
Power Connector | MS90556-C-32412P | |
Maximum Gross Weight | 11,900 lbs. | |
Tare Weight | 2,673 lbs. | |
Payload Capacity | 8,745 lbs. | |
Internal Volume | 155 cu. ft. | |
Operating Temperature Range | -25 to 125°F | |
Storage Temperature Range | -50 to 160°F | |
Minimum Circuit Ampacity | 15amps at 208VAC 50/6 0 Hz | |
Requires Y connection w /neutral | ||
Refrigerant Charge | 6.5 lbs. R-404A |
Contact: Send us an email – militarysales@mainstream-engr.com
Phone: 321-631-3550
Container
TriCon Refrigerated Container System (TRCS)
![Single-Door_Back-View_SIL_SWOOSH](https://mainstream-engr.com/wp-content/uploads/2021/09/Single-Door_Back-View_SIL_SWOOSH.png)
Mainstream’s Tricon Refrigerated Container System (TRCS) is the official TRCS used by the U.S. Armed Forces and is the only TRCS verified to meet MIL-PRF-32335. TRCS is an eight-foot by eight-foot by six-foot six-inch (8′ X 8′ X 6′ 6″) insulated container with Mainstream’s Modular Refrigeration Unit (MRU) that is powered by an external power source and capable of storing and transporting temperature sensitive cargo. Our MRU maintains the insulated container at freezer or refrigerator temperature ranges in ambient temperatures ranging from -25 to +125°F. Mainstream’s TRCS is certified by NSF International to satisfy sanitary requirements of NSF/ANSI 7 Standard for Commercial Refrigerators and Freezers. It is ISO 1496-2 tested and CSC approved. The Type III TRCS variant is equipped with interior shelving units with a 600 lbs.-per-shelf capacity and both interior and exterior lighting. The TRCS operates with 208 VAC, 50/60 Hz, three-phase power input.
Tested to U.S. Military Standard 810
Official Modular Refrigeration Unit used by the U.S. Military
- Type I – Electrically Powered RU with Full-Width Double Door
- Type III – Electrically Powered RU with Single-Man Door
- Verified to Meet MIL-PRF-32335 Requirements
- ISO Tested and CSC Approved
- NSF/ANSI Standard 7 Certified
- High Efficiency with Energy Saver Option
- MTBF 5,022 hrs.
- 20 Year Storage
- Portable Exterior Lighting System (PELS)
Standard on Type III, Optional on Type I
TRCS/MRU Value-Added Features
Designed for Military Environment
The MRU was designed for the harsh military environment. The unit has been tested to MIL-STD-810G (e.g., salt-fog, humidity, sand-dust, solar, ice & freezing rain, blowing rain and watertightness, EMI [RE102 and CE102], high and low temperature operation & storage, ground mobility, rail impact and transit drop).
Improved Air Flow and Air Circulation
Air is drawn into the evaporator so condensation is not sprayed onto the food inside the container. The conditioned air circulates radially from the evaporator compartment to provide more uniform air flow distribution and prevent air blockage.
Total Unit Modularity
Every component can be replaced with common tools. Tube brazing or wire splicing is never required.
NSF Food Grade Shelving Units
The TRCS can be outfitted with NSF certified removable stainless steel shelving units consisting of five 22″ wide shelves spanning the length on each side of the container (standard on Type III, optional on Type I).
PELS Lighting System
Available with an approved Portable Exterior Light System (PELS) with magnetic mounting bracket for attachment anywhere on the exterior of the TRCS (standard on Type III, optional on Type I).
Interior Lights
Available with an approved Interior (White and Black-out) LED lighting system (standard on Type III).
System Redundancy
Component redundancy allows the MRU to operate even if a condensor fan, evaporator fan, fan capacitor or heater fails. Extra terminals are available on the relays if a contact pits and fails.
Energy Saver Option
In freezer mode, an energy saver selection switch automatically operates the MRU longer during cooler periods of the day, such as the evening, to reduce power consumption.
Circuit Breakers
The MRU uses re-settable circuit breakers; there are no fusible links or fuses.
Physical | Type I | Type III | ||
---|---|---|---|---|
Size | 96″ x 77.5″ x 96″ | 96″ x 77.5″ x 96″ | ||
Doors | full-width double door | single-man door | ||
PELS Light | Optional | Included/Standard | ||
Removable Stainless Steel Shelves | Optional | (5) 22″ wide shelves included/Standard | ||
Power Connector | MS90556-C-32412P | MS90558-C-32412P | ||
Maximum Gross Weight | 26,460 lb | 26,460 lb | ||
Tare Weight | 3,880 lb | 4,630 lb | ||
Payload Capacity | 22,580 lb | 21,830 lb | ||
Operating Temperature Range | -25 to 125°F | -25 to 125°F | ||
Storage Temperature Range | -50 to 160°F | -50 to 160°F | ||
Minimum Circuit Ampacity | 15 amps at 208 VAC 50/60 Hz Requires Y connection w/neutral | 15 amps at 208 VAC 50/60 Hz Requires Y connection w/neutral | ||
Refrigerant Charge | 6.5 lbs R-404A | 6.5 lbs R-404A |
NSN (National Stock Number) | ||
---|---|---|
Type I | 8145-01-598-4828 | |
Type III | 8145-01-598-4829 | |
Type III PELS | 6230-01-630-7370 |
Contact: Send us an email – militarysales@mainstream-engr.com
Phone: 321-631-3550