Refrigeration

Modular Refrigeration Unit (MRU)

Edit Content

Modular Refrigeration Unit (MRU) provides thermal control to insulated containers in ambient temperatures as high as 130°F and as low as -40°F. Both the MRU-TQ1-404 and MRU-TQ3-404 can be rigidly attached to either the Tricon or Quadcon insulated containers. The MRU is designed to replace the Thermo King VM405 and the Carrier Integra 30S with improved performance, reliability, and ease of maintenance. Using a high-efficiency, environmentally safe refrigerant, the MRU meets or exceeds all requirements for military container heating and cooling.

Tested to U.S. Military Standard 810 – Official Modular Refrigeration Unit used by the U.S. Military

  • Designed for high ambient temperatures and desert conditions
  • Designed for maintenance or repair with common tools from standard military tool kits
  • Mean Time Between Failure (MTBF) rate of 5,202 hours
  • 20-year storage life without performance degradation
  • Designed for maintenance or repair with common tools from standard military tool kits
  • Straightforward, intuitive control panel
  • Integrated LCD that simplifies temperature and defrost settings
  • 18 LED status indicators and nine jumpers located on the PCB allow user override of sensors and relays
  • Wire harnesses are straightforward plug and play
  • Brazing, soldering or wire splicing never required
Edit Content
MRU SPECIFICATIONS
Physical
Height 21.4 inches 54.3 cm
Width 36.8 inches 93.3 cm
Depth 38 inches 96.5 cm
Weight 350 lbs 158.8 kg
Electrical Power
MRU-TQ1-404 120 VAC, single-phase, 60Hz
MRU-TQ3-404 208 VAC, 3-phase, 50/60 Hz Y Connection w/Neutral
Cooling Capacity
MRU-TQ1-404 2,800 BTU/hr (820 W) at 0°F/100°F 6,600 Btu/hr (1,933 W) at 35°F/100°F
MRU-TQ3-404 4,100 Btu/hr (1,200 W) at 0°F/100°F 9,750 Btu/hr (2,857 W) at 35°F/100°F
Refrigerant R-404A 6 lbs 8 oz
Set Up Time – The MRU can be installed in less than 30 minutes by two personnel and is operable by a soldier outfitted in all levels of Mission Oriented Protective Posture (MOPP) equipment. The MRU requires less than 90 minutes Mean Time To Repair (MTTR) including evacuation and recharging using standard, commercial support and test equipment.
Edit Content

Operating Hours: Monday – Friday 8:00 a.m. – 5:00 p.m. EST

Contact: Send us an email – militarysales@mainstream-engr.com
Phone:  321-631-3550